Envirco IsoClean 400 and 400UV: Portable HEPA Selection Guide

Plan compact portable HEPA filtration with verified airflow, room-volume calculations and a clear distinction between recirculation and exhaust applications.

Start with your project requirements

Use our product selection tools to prepare the equipment details for review.

Find Envirco products and parts

The Envirco IsoClean 400 is a compact, portable HEPA air-cleaning unit for applications where a movable system is useful. The 400UV version adds an internal UV-C lamp. Both require selection around the room, operating mode and installed airflow.

Tillman & Associates helps South Texas facilities compare portable filtration options and collect the information needed for a project review.

Use the airflow from the applicable literature

The manufacturer’s web overview describes up to 400 CFM, while its currently linked data sheet and installation manual specify a 70–370 CFM range for the 400. This guide uses the 370 CFM maximum from those documents for planning examples. Confirm the exact model, revision and installed operating point with Tillman before ordering.

The linked data sheet lists solid-state speed adjustment and a HEPA filter with a minimum efficiency of 99.99% at 0.3 micron. Lower fan settings and added resistance can change the airflow available for the application.

Room volume matters more than floor area alone

A basic airflow-to-volume calculation is airflow-equivalent ACH = CFM × 60 ÷ room volume in cubic feet. Room volume is length × width × ceiling height.

For example, a 20-by-25-foot room with a 10-foot ceiling contains 5,000 cubic feet. At 370 CFM, the nominal airflow-equivalent rate is approximately 4.4 per hour. This is an illustrative flow calculation, not a tested CADR, room-clearance time or compliance determination. Use the actual delivered airflow and project design assumptions for the final review.

Recirculation and exhaust are different arrangements

In recirculation mode, the unit filters air and returns it to the room. An exhaust arrangement moves air out of the space through a configured duct connection. A negative-pressure application needs the exhaust arrangement and room airflow balance reviewed together; simply running a recirculating unit does not establish room containment.

CDC guidance notes that portable HEPA recirculation does not satisfy outdoor-air requirements and that placement affects air-cleaning performance. Coordinate healthcare applications with the facility’s engineering and infection-prevention teams.

What the UV version adds

The manufacturer’s manual describes the optional lamp as helping disinfect the filter face. Specify the UV version when that feature is required, and follow the applicable service instructions. The UV option does not establish a universal pathogen-reduction percentage or guarantee that the room is disinfected.

Placement and maintenance planning

Show the proposed location, nearby furniture, access routes and any exhaust duct on the request. Leave the intake, discharge and service access usable. Include the unit label and filter identification when requesting replacement parts so the supplied configuration can be checked.

Details to send Tillman

  • Room length, width and ceiling height, plus intended use.
  • Required air-cleaning airflow or project air-change target.
  • Recirculation or exhaust mode, with the proposed duct route if applicable.
  • Available voltage, frequency, outlet and circuit information.
  • Operating schedule, sound constraints, placement and service clearance.
  • Quantity, UV option, accessories and existing unit labels if replacing equipment.

Send your IsoClean requirements to Tillman. We support Houston, San Antonio, Austin, Corpus Christi, Beaumont, College Station, Galveston and surrounding South Texas communities.

Common IsoClean 400 questions

Why does this guide use 370 CFM?

That is the maximum in the manufacturer’s currently linked data sheet and manual; the web overview uses 400 CFM. We can confirm the applicable selection.

Does one unit provide six air changes in any 500-square-foot room?

No. Ceiling height, actual airflow and the project’s calculation basis must be included.

Which larger models should I compare?

Review the IsoClean 800 and IsoClean CM with Tillman.